Showing 1–12 of 29 results

Scelerisque a per non a condimentum

Dis adipiscing a laoreet inceptos adipiscing est per ullamcorper malesuada mi vestibulum elementum tempus leo parturient habitant ut a.Consectetur gravida et ultricies eu parturient convallis aliquam id nam hendrerit vestibulum nec.

Scelerisque a per non a condimentum

Dis adipiscing a laoreet inceptos adipiscing est per ullamcorper malesuada mi vestibulum elementum tempus leo parturient habitant ut a.Consectetur gravida et ultricies eu parturient convallis aliquam id nam hendrerit vestibulum nec.

Scelerisque a per non a condimentum

Dis adipiscing a laoreet inceptos adipiscing est per ullamcorper malesuada mi vestibulum elementum tempus leo parturient habitant ut a.Consectetur gravida et ultricies eu parturient convallis aliquam id nam hendrerit vestibulum nec.

Scelerisque a per non a condimentum

Dis adipiscing a laoreet inceptos adipiscing est per ullamcorper malesuada mi vestibulum elementum tempus leo parturient habitant ut a.Consectetur gravida et ultricies eu parturient convallis aliquam id nam hendrerit vestibulum nec.

R001 | Pump group with variable point mixing

Pump group with variable point mixing, complete with a 3-way mixing valve regulated by a three-point modulating bidirectional rotary electric actuator, connectable to weather-compensated controllers; the valve features a bypass that draws water from the system return and feeds it into the flow circuit to achieve the desired fluid temperature. The circulator, with 1 1/2” connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous flow and return temperature readings (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, or with the flow circulator on the right or left (in case of on-site changes, please follow the instructions in the technical data sheet included in the packaging); the unit is supplied with a black EPP insulating shell. The supply includes actuator art. 787 (specify 230 or 24 V voltage). Technical datasheet Instruction sheet Declaration of conformity

3D Models

R002 – Mixing group with fixed point regulating unit

Recirculation unit with fixed-point mixing, complete with a 3-way mixing valve controlled by a thermostatic head with a remote sensor (item no. 995), to be positioned in contact with or immersed in the system’s supply pipe in order to achieve the desired fluid temperature (adjustment range 20°C–50°C). The valve is equipped with a bypass that draws part of the water from the system return, introducing it into the supply circuit to achieve the desired fluid temperature. The circulator, with 1"1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The booster unit is fitted with two ball shut-off valves with an integrated thermometer for instant reading of the supply and return temperatures (the return ball valve incorporates a check valve). The booster unit can be ordered without a circulator, with a supply circulator on the right or on the left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the unit is supplied with a black PPE insulating shell. The supply of the unit includes the thermostatic head art. 995 with 30x1.5 connections. Technical datasheet Instruction sheet Declaration of conformity

3D Models

R003 – Booster set for high/low direct temperature

High/low direct temperature control unit, suitable for systems with radiators, fan coils and heated towel rails. The circulator, with 1½-inch connections, is available in either an asynchronous (not available for sale in the EU) or electronic version. The pump set features two ball shut-off valves with built-in thermometers for instantaneous reading of flow and return temperatures (the return ball valve includes an integrated check valve) and a ball valve to isolate the circulator. The pump set can be ordered without a circulator or with the flow circulator on the right; the circulator can be easily moved to the left. The set is supplied with a black EPP insulation shell. Technical datasheet Instruction sheet Declaration of conformity

3D Models

R004 – Pump group with fixed-point mixing

Pump group with fixed-point mixing, complete with thermostatic mixing valve. By setting the operating temperature on the mixing valve, effective control of the system flow temperature is achieved when it differs from that of the heat generator. Two different thermostatic valves are available with different operating ranges (20-50°C / 30-70°C). The circulator, with 1”1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous reading of the flow and return temperatures (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, with the flow circulator on the right or left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the group is supplied with a black EPP insulating shell. When ordering, please specify the required temperature (between 20-50°C or 30-70°C), replacing the dots (where present) with the number corresponding to the temperature; for example, when ordering: R004 DX with P328 circulator and 20-50°C temperature, the code will be: 94R004AED55P328 (in the case of 30-70°C temperature, indicate 70 instead of the dots). Technical datasheet Instruction sheet Declaration of conformity

3D Models

R005 – Anti-condensation mixing group

Anti-condensation circulation station, 1" male connections. The station consists of two ball valves with built-in thermometer for instant reading of flow and return temperature. The station can be ordered without circulator, with asynchronous circulator (not for sale in EU), with electronic circulator mounted on the right or left. This item includes 1" anti-condensation valve, available in 45°, 55°, 60°, 70° settings. When ordering, specify the required setting by adding the number corresponding to the setting in place of the dots; example when ordering: R005 DX with circulator P328 and 55° anti-condensation, the code will be: 94R005AED55P328. Technical datasheet Instruction sheet Declaration of conformity

3D Models

781 | Tee fitting for connecting the mixing unit components

Tee fitting for connecting the mixing unit components to manage the flow return to the system.

782 | Mixing group with variable point regulation unit

Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature. PLEASE NOTE: the servomotor art. 787 is not included. Technical datasheet

783 | Fixed-point mixing unit

Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included. Technical datasheet

3D Models

786 | Thermostatic mixing group

Thermostatic mixing group, consisting of a regulated 4-way mixing valve with 90° inlets, designed for pump and manifold connection. Adjustment ranges 20°C - 50°C: code 93786AE052050 / 30°C - 70°C: code 93786AE053070. Technical datasheet

3D Models

785 | Brass manifold for pump groups

NOTE: in case of reduction for the boiler inlet connection, use art. 789. Double-chamber brass manifold suitable for pump groups art. R001-R002-R003, complete with black EPP insulation shell. Art. 785 manifolds can be used individually or connected in series (up to 6) to serve multiple circuits, simplifying installation and reducing the overall footprint. The package includes nuts, bolts, and two O-rings for closing a single manifold or connecting multiple manifolds together. NOTE: art. 790 end caps and art. 788 mounting bracket are not included. Ordering examples: 1 single manifold: 1x art. 785 + 2x art. 790 2 manifolds in series: 2x art. 785 + 2x art. 790 + 2x art. 173 3 manifolds in series: 3x art. 785 + 2x art. 790 + 4x art. 173 4 manifolds in series: 4x art. 785 + 2x art. 790 + 6x art. 173 5 manifolds in series: 5x art. 785 + 2x art. 790 + 8x art. 173 6 manifolds in series: 6x art. 785 + 2x art. 790 + 10x art. 173 Technical datasheet Declaration of conformity

3D Models

788 | Wall mounting kit for circulation pump groups

Wall mounting kit for circulation pump groups R001-R002-R003 consisting of 1 support bracket with screws and rawl plugs.