Showing all 9 results

Show sidebar
1102
Close

1102 | Single distribution manifold

Single distribution manifold. 1/2” female side connections. Interaxe: 50 mm. Declaration of Conformity
Single distribution manifold
Close

1103 | Single distribution manifold

Single distribution manifold. Outlets for 1/2” air vent (art.700) and 1/2” drain cock (art.172). Female outlets. Interaxe: 50 mm. Declaration of Conformity
1104
Close

1104 | Single distribution manifold with pre-assembled fittings

Single distribution manifold with pre-assembled fittings. Male outlets. Interaxe: 50 mm. Suitable for 3/4” Euroconus fittings. Technical data sheet Declaration of Conformity
178
Close

178 | Insulators for 1” and 1”1/4 single bar manifolds

Insulators for 1” and 1”1/4 single bar manifolds. For manifolds 1” up to 12 outlets, for manifolds 1”1/4 up to 15 outlets. The insulators can be cut to insulate manifolds with a lower number of outlets. Suitable for distribution manifolds. Holes on one side with 50 mm interaxe.
210
Close

210 | Collettore complanare doppio componibile

Double fit-together coplanar manifold with interception valves. For heating and sanitary systems. With hot/cold plates: one side red - the other side blue. 1/2” male side connections. Side male outlets with interaxe 37,5 mm. Distance between head outlets 50 mm. Technical data sheet Declaration of Conformity
213 214
Close

213 – 214 | Fit-together coplanar manifold

Fit-together coplanar manifold. Side male outlets with interaxe 37,5 mm. Distance between head outlets 50 mm. Technical data sheet Declaration of Conformity
modular single manifold
Close

222 – 223 – 224 – 186 | Male/Female modular single manifold

Male/Female modular single manifold, side exits Male 1/2” with conical seat (art.222), 1/2” with flat seat (art.224), 24x1,5 (art.223), Euroconus (art.186). Articles 222, 223 and 224 with inter-axe between outlets 37,5 mm., art. 186 with inter-axe between outlets 50 mm. Technical data sheet Declaration of Conformity
227
Close

227 – 228 – 229 | Fit-together single manifold with interception valves

Fit-together single manifold with interception valves. 3/4” head connections with interaxe 37,5 mm and 1” head connection with interaxe 50 mm. 1/2”, M24x1,5 and 3/4” side connections. It includes: hot/cold plates: one side red, the other side blue and double face plates with descriptions for sanitary and heating system in the following languages: Italian, Russian, English, Spanish, Greek, Hungarian. Technical data sheet Declaration of Conformity
PRODUCT CERTIFICATION
Coplanar manifold
Close

230 – 232 | Coplanar manifold

Coplanar manifold. 1/2” and 24x1,5 side male outlets with interaxe 37,5. Distance between head outlets 50 mm. Technical data sheet Declaration of Conformity