Art. | Code | |
790 | 87790AF05 | 1 |
Related products
K062 | Delivery pump group
Delivery pump group. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1”½ connections. The mixing unit includes safety thermostat (art. P310) and manual air vent (art. 705 1/2”), it can be installed on the left or right side of the manifold. 1” connection. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical data sheet
Declaration of Conformity
797 | Flat seat Male-Female connector with gaskets on both sides
Flat seat Male-Female connector with gaskets on both sides. Reduction from 1” ½ M to 1”F.
Technical data sheet
Declaration of Conformity
R001 – Mixing group with variable point regulating unit
Mixing group with variable point regulating unit. It is provided with a three way mixing valve regulated by a 3-point modulating and bidirectional rotating electric servomotor, connectable to regulating control units; the valve has a By-Pass which brings a portion of the return side flow into the delivery side to obtain the desired temperature of the fluid. The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump, with delivery pump to the right or to the left-hand (in case of any changes on site please follow the technical sheet instructions included in the package); the group is supplied with a black PPE insulated shell.
The mixing unit is supplied with the servomotor art. 787 (230 or 24 voltage).
Technical data sheet
Instruction Sheet
Declaration of Conformity
P310 | Safety thermostat
Safety thermostat. Suitable for underfloor systems with high temperature boiler supply. It stops the pump when reaching 50˚C.
Technical data sheet
M058 | Mixing group with fixed point regulating unit with circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical data sheet
Declaration of Conformity
R003 – Mixing group for high/low direct temperature unit
Mixing group for high/low direct temperature unit, suitable for radiators systems, fan coils, design radiators, radiation heating and boilers. The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump or with delivery pump to the right; the pump can be easily moved to the left. The group is supplied with a black PPE insulated shell.
Technical data sheet
Instruction Sheet
Declaration of Conformity
789 | Plane seat union with nut and gasket
1”1/2 plane seat union with nut and gasket. It reduces from 1”1/2 to 3/4” F or from 1”1/2 to 1” F the lower connection of art. R001, R002, R003 and 785.
Technical data sheet
Declaration of Conformity
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical data sheet