790 | Cap for manifold head art. 785
Codes and dimensions
| Art. | Code | |
| 790 | 87790AF05 | 1 |
Related products
R002 – Mixing group with fixed point regulating unit
Recirculation unit with fixed-point mixing, complete with a 3-way mixing valve controlled by a thermostatic head with a remote sensor (item no. 995), to be positioned in contact with or immersed in the system’s supply pipe in order to achieve the desired fluid temperature (adjustment range 20°C–50°C). The valve is equipped with a bypass that draws part of the water from the system return, introducing it into the supply circuit to achieve the desired fluid temperature. The circulator, with 1"1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The booster unit is fitted with two ball shut-off valves with an integrated thermometer for instant reading of the supply and return temperatures (the return ball valve incorporates a check valve). The booster unit can be ordered without a circulator, with a supply circulator on the right or on the left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the unit is supplied with a black PPE insulating shell. The supply of the unit includes the thermostatic head art. 995 with 30x1.5 connections.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
Technical datasheet
3D Models
797 | Male-female flat seat fitting complete with gaskets
Male-female flat seat fitting complete with gaskets on both sides. Reduces from 1" 1/2"M to 1"F.
Technical datasheet
Declaration of conformity
M058 | Mixing group with fixed point regulating unit with circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
P310 | Safety thermostat
Safety thermostat. Suitable for underfloor systems with high temperature boiler supply. It stops the pump when reaching 50˚C.
Technical datasheet
787 | Electric servomotor
3-point rotating electric servomotor (modulating and bidirectional). It is installed on the mixing valve by means of a screw. Rotation angle 90°. The servomotor can also work manually by means of its switch. For the proper functioning and connection please refer to the instructions in the technical sheet.
Technical datasheet