- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
R003 – Booster set for high/low direct temperature
High/low direct temperature control unit, suitable for systems with radiators, fan coils and heated towel rails. The circulator, with 1½-inch connections, is available in either an asynchronous (not available for sale in the EU) or electronic version. The pump set features two ball shut-off valves with built-in thermometers for instantaneous reading of flow and return temperatures (the return ball valve includes an integrated check valve) and a ball valve to isolate the circulator. The pump set can be ordered without a circulator or with the flow circulator on the right; the circulator can be easily moved to the left. The set is supplied with a black EPP insulation shell.
3D Models

Cod. 93R003…

Cod. 94R003…
| Art. | Size | Delivery side | Boiler connection | System connection | Code | Pump | Circulator control signal | |||
| ON/OFF | PWM | |||||||||
| R003 | DN20 | R | 1"1/2 M | 3/4 F | 93R003AED05 | NO PUMP | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 3/4 F | 93R003AEDP327 | Wilo Para 25/8 | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 3/4 F | 93R003AEDP329 | Taco ES2 25/60 | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 3/4 F | 93R003AEDP330 | Wilo Para 25/7 | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 3/4 F | 93R003AEDP331 | Shinoo GPA 25/70 III* | ✔ | ✔ | 1 | |
| R003 | DN20 | R | 1"1/2 M | 1” M | 94R003AED05 | NO PUMP | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 1” M | 94R003AEDP327 | Wilo Para 25/8 | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 1” M | 94R003AEDP329 | Taco ES2 25/60 | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 1” M | 94R003AEDP330 | Wilo Para 25/7 | ✔ | X | 1 | |
| R003 | DN20 | R | 1"1/2 M | 1” M | 94R003AEDP331 | Shinoo GPA 25/70 III* | ✔ | ✔ | 1 | |
The product with UPS 25/65 pump is sold in non-EU countries that have not joined the EUP regulations.
* PWM signal cable not included. To be purchased separately (see cables)when connecting to a PWM signal controller.
You may also like…
P320 – P321 | Asynchronous circulator
P327 | Electronic circulator WILO PARA RS 25/8
Electronic circulator WILO PARA RS 25/8, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves. Power supply cable included.
Instruction Sheet
P328 | Grundfos UPM3 HYBRID 25-70 electronic circulator
Grundfos UPM3 HYBRID 25-70 electronic circulator, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves, AUTO ADAPT, PWM signal. POWER SUPPLY CABLE INCLUDED. The pump can be controlled via PWM signal. PWM signal cable NOT INCLUDED.
Instruction Sheet
P330 | Electronic circulator WILO PARA RS 25/7
Related products
R002 – Mixing group with fixed point regulating unit
Recirculation unit with fixed-point mixing, complete with a 3-way mixing valve controlled by a thermostatic head with a remote sensor (item no. 995), to be positioned in contact with or immersed in the system’s supply pipe in order to achieve the desired fluid temperature (adjustment range 20°C–50°C). The valve is equipped with a bypass that draws part of the water from the system return, introducing it into the supply circuit to achieve the desired fluid temperature. The circulator, with 1"1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The booster unit is fitted with two ball shut-off valves with an integrated thermometer for instant reading of the supply and return temperatures (the return ball valve incorporates a check valve). The booster unit can be ordered without a circulator, with a supply circulator on the right or on the left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the unit is supplied with a black PPE insulating shell. The supply of the unit includes the thermostatic head art. 995 with 30x1.5 connections.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
R005 – Anti-condensation mixing group
Anti-condensation circulation station, 1" male connections. The station consists of two ball valves with built-in thermometer for instant reading of flow and return temperature. The station can be ordered without circulator, with asynchronous circulator (not for sale in EU), with electronic circulator mounted on the right or left.
This item includes 1" anti-condensation valve, available in 45°, 55°, 60°, 70° settings.
When ordering, specify the required setting by adding the number corresponding to the setting in place of the dots; example when ordering: R005 DX with circulator P328 and 55° anti-condensation, the code will be: 94R005AED55P328.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
Technical datasheet
3D Models
173 | End cap with O-ring
End cap with O-ring to close 1” exits of manifold art. 785.
Declaration of Conformity
796 | Flat seat union complete with swivel cap nut and gasket
Flat seat union female-female complete with swivel cap nut and gasket. Reduces from 1"F (flat seat seal) to 1" 1/2"F.
Technical datasheet
Declaration of conformity
797 | Male-female flat seat fitting complete with gaskets
Male-female flat seat fitting complete with gaskets on both sides. Reduces from 1" 1/2"M to 1"F.
Technical datasheet
Declaration of conformity
M058 | Mixing group with fixed point regulating unit with circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
M060 | Mixing group with fixed point regulating unit with circulating pump and thermostatic with remote sensor
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-70°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet