- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
786 | Thermostatic mixing group
Thermostatic mixing group, consisting of a regulated 4-way mixing valve with 90° inlets, designed for pump and manifold connection. Adjustment ranges 20°C – 50°C: code 93786AE052050 / 30°C – 70°C: code 93786AE053070.
3D Models
0
People watching this product now!
Codici e dimensioni
| Art. | Misura | Attacchi caldaia | Attacchi impianto | Attacchi ritorno | Codice | |
| 786 | DN20 | 1”1/2 M | 1"1/2 F | 1” M | 93786AE052050 | 1 |
| 786 | DN20 | 1”1/2 M | 1"1/2 F | 1” M | 93786AE053070 | 1 |
Related products
R001 | Pump group with variable point mixing
Pump group with variable point mixing, complete with a 3-way mixing valve regulated by a three-point modulating bidirectional rotary electric actuator, connectable to weather-compensated controllers; the valve features a bypass that draws water from the system return and feeds it into the flow circuit to achieve the desired fluid temperature. The circulator, with 1 1/2” connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous flow and return temperature readings (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, or with the flow circulator on the right or left (in case of on-site changes, please follow the instructions in the technical data sheet included in the packaging); the unit is supplied with a black EPP insulating shell.
The supply includes actuator art. 787 (specify 230 or 24 V voltage).
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
R004 – Mixing group with fixed point regulating unit
Mixing group with fixed point regulating unit, equipped with thermostatic mixing valve. By setting the working temperature on the mixing valve, you get an effective control of the plant delivery temperature when it is different from the heat generator one. Two thermostatic valves are available with different working temperature (20-50°C / 30-70°C). The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump, with delivery pump to the right or to the left-hand (in case of any changes on site please follow the technical sheet instructions included in the package); the group is supplied with a black PPE insulated shell.
When placing the order please specify the requested temperature (between 20-50 °C or 30-70 °C), by filling in the dotted line (between the pump position and the pump code) with the number corresponding to the temperature. For example, if you order R004 R with circulator P328 and temperature 20°-50 ° C, the code will be: 94R004AED55P328 (in case of temperature 30-70 ° C please fill in the dotted line with 70).
Technical datasheet
Instruction Sheet
Declaration of Conformity
R005 – Anti-condensation mixing group
Anti-condensation mixing group, 1 “male connections. It is equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures. It can be ordered without pump, with asynchronous pump (not for sale in the EU), with electronic pump to the right or to the left-hand. The group includes an anti-condensation valve, 1”, available settings: 45 °, 55 °, 60 °, 70 °.
When placing the order please specify the requested temperature setting, by filling in the dotted line with the number corresponding to the temperature setting. For example, if you order R005 R with circulator P328 and 55 °anti-condensation, the code will be: 94R005AED55P328.
Technical datasheet
Instruction Sheet
Declaration of Conformity
782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
Technical datasheet
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
Technical datasheet
3D Models
785 | Brass manifold for pump groups
NOTE: in case of reduction for the boiler inlet connection, use art. 789.
Double-chamber brass manifold suitable for pump groups art. R001-R002-R003, complete with black EPP insulation shell. Art. 785 manifolds can be used individually or connected in series (up to 6) to serve multiple circuits, simplifying installation and reducing the overall footprint. The package includes nuts, bolts, and two O-rings for closing a single manifold or connecting multiple manifolds together.
NOTE: art. 790 end caps and art. 788 mounting bracket are not included.
Ordering examples:
1 single manifold: 1x art. 785 + 2x art. 790
2 manifolds in series: 2x art. 785 + 2x art. 790 + 2x art. 173
3 manifolds in series: 3x art. 785 + 2x art. 790 + 4x art. 173
4 manifolds in series: 4x art. 785 + 2x art. 790 + 6x art. 173
5 manifolds in series: 5x art. 785 + 2x art. 790 + 8x art. 173
6 manifolds in series: 6x art. 785 + 2x art. 790 + 10x art. 173
Technical datasheet
Declaration of conformity
3D Models
788 | Wall mounting kit for circulation pump groups
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity



