- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
Showing 1–12 of 53 results
K054 – K056 – K058 | Pre-assembled group with box for radiant panel systems and radiators
Pre-assembled group with box. For radiant panel systems with low temperature circuits and for radiators with high temperature circuits, high temperature supply, fixed point mixing unit. It is supplied with pump P328 (Grundfos UPM3 Hybrid) and safety thermostat P310 installed in the box. Choose electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
K060 | Pre-assembled for radiant panel systems with low temperature circuits
Pre-assembled group with box. For radiant panel systems with low temperature circuits, high temperature supply, fixed point mixing unit. It is supplied with pump P328 (Grundfos UPM3 Hybrid) and safety thermostat P310 installed in the box. Choose electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
A1K013 | Pre-assembled group for radiant panel systems with low temperature circuits
Pre-assembled group for radiant panel systems with low temperature circuits, supplied at high-temperature with fixed-point three-way mixing system with differential maximum pressure valve and flow meter. It is supplied without circulator and complete with thermostatic head 20°-50°C with remote sensor.
Choose thermostatic and electrothermic actuators with M28x1,5 connection thread.
Combinable with pumps P320, P321, P326, P327, P328, P330.
ROHS Declaration
A2K013 | Pre-assembled group for radiant panel systems with low temperature circuits
Pre-assembled group for radiant panel systems with low temperature circuits, supplied at high-temperature with fixed-point two-way mixing system. It is supplied without circulator and complete with thermostatic head 20°-50°C with remote sensor.
Choose thermostatic and electrothermic actuators with M28x1,5 connection thread.
Combinable with pumps P320, P321, P326, P327, P328, P330 (page 182).
ROHS Declaration
A3K013 | Pre-assembled group for radiant panel systems with low temperature circuits – Complete with thermostatic head
Pre-assembled group for radiant panel systems with low temperature circuits, supplied at high-temperature with fixed-point two-way mixing system. It is supplied without circulator and complete with thermostatic head 20°-50°C with remote sensor.
Choose thermostatic and electrothermic actuators with M28x1,5 connection thread.
Combinable with pumps P320, P321, P326, P327, P328, P330 (page 182).
ROHS Declaration
K025 – K026 | Manifolds unit with memory flowmeters and valves with thermostatic option – With straight ball valve
Manifolds unit with manual/thermostatable shut-off and adjustment, with flow meters. It includes:
Includes: 2 straight ball valves (item 215), ball valve socket connection with flat-seat O-ring seal on the manifold, 2 mounting brackets (item 208) with anti-vibration seals, 2 x 1” M-F intermediate fittings with swivel connection (our item no. 204). Item no. 204 can also be fitted between the manifold and the ball valve, 2 x 3/8” automatic air vent valves (item no. 700), 2 x 1/2” water drain valves (item 172), 2 x 1” thermometer sockets with O-ring seals (item 185), 2 x 0-60° thermometers (item 206). Threaded connection for 3/4 Euroconus or M24x1.5 fittings. Select electrothermal controls with a 28x1.5 connection.
Technical datasheet
Declaration of conformity
ROHS Declaration
3D Models
K025 – K026 | Manifolds unit with memory flowmeters and valves with thermostatic option – With angle ball valve
Manifolds unit with memory flowmeters and valves with thermostatic option. It includes: 2 ball valves (art. 225), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1” male/female intermediate fittings with revolving connection (art.204). Conical sealing gasket. Art.204 can be assembled between manifold and ball valve. 2 3/8” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
ROHS Declaration
K031 – K032 | Manifolds unit with memory flowmeters and valves with thermostatic option – With straight valve
Manifolds unit with memory flowmeters and valves with thermostatic option.
It includes: 2 ball valves (art.215), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1/2” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
ROHS Declaration
1017 | Stainless steel return manifold with manual valves and valves with thermostatic option
Stainless steel return manifold with manual/thermostatable valves. Male exits. Distance between outlets 50 mm. Threaded connection for 3/4-inch Euroconus fittings. Select electrothermal controls with a 28x1.5 connection.
Technical datasheet
Instruction sheet
Declaration of conformity
ROHS Declaration
Installation guide for the M28 actuator
1018 | Stainless steel return manifold with manual valves and valves with thermostatic option – M30
Stainless steel return manifold with manual/thermostatable valves. Male exits. Distance between outlets 50 mm. Thread for fittings 3/4 Euroconus. Choose electrothermal controls with 30x1.5 connection. Compatible with ICMA M30 electrothermal actuators, Innoakt INN920066PL, Taconova NOVADRIVE 257.2855.000, Taconova TOPDRIVE 257.2055.000, Caleffi 656102 (4 wires), Siemens STA321.65L10, Imi hydronic Emo-t and Intellisys MCA230 (4 wires), Danfoss 088H3220.
Technical datasheet
Instruction sheet
Declaration of conformity
ROHS Declaration
Installation guide for the M30 actuator
1021 | Stainless steel delivery manifold with micrometric regulation lockshields
Stainless steel delivery manifold with micrometer-adjustable holders. Male exits. Distance between outlets 50 mm. Threaded connection for 3/4-inch Euroconus fittings.
Technical datasheet
Instruction sheet
Declaration of conformity
ROHS Declaration
Installation guide for the M28 actuator
1025 | Stainless steel delivery manifold with flow meters
Stainless steel delivery manifold with flow meters. Male exits. Distance between outlets 50 mm. Suitable for 3/4” Euroconus fittings.
Technical datasheet
Instruction sheet
Declaration of conformity
ROHS Declaration


