Balancing valves for hydraulic circuits, hydraulic compensators and stubs (8)

Thermostatic mixers, shock absorbers, mixing valves (9)

Showing 1–12 of 17 results

Show sidebar
142
Close

142 | Thermostatic mixer with tails on the three ways

Thermostatic mixer, with tails on the three ways. Max. working pressure 10 bars, max. working temperature 85°C, temperature setting on mixed way 30-65°C. Hot water side inlet, cold water lower inlet, side mixed way. Technical data sheet Declaration of Conformity
143
Close

143 | Thermostatic mixer with female connections

Thermostatic mixer with female connections. Max. working pressure 10 bars, max. working temperature 85°C, temperature setting on mixed way 30-65°C. Hot water side inlet, cold water lower inlet, side mixed way. Technical data sheet Declaration of Conformity
144
Close

144 | Thermostatic mixer with tails on the three ways

Thermostatic mixer, with tails on the three ways, check valves on hot/cold water ways. Max. working pressure 10 bars, max. working temperature 85°C, temperature setting on mixed way 30-65°C. Hot water side inlet, cold water lower inlet, side mixed way. Technical data sheet Declaration of Conformity
145
Close

145 | Thermostatic mixer with male connections

Thermostatic mixer with male connections. Max. working pressure 10 bars, max. working temperature 85°C, temperature setting on mixed way 30-65°C. Hot water side inlet, cold water lower inlet, side mixed way. Technical data sheet Declaration of Conformity
148
Close

148 | Thermostatic mixer with tails on the three ways

Thermostatic mixer, with tails on the three ways. Max. working pressure 10 bars, max. working temperature 85°C, temperature setting on mixed way 30-65°C. Side hot/cold water inlets, lower mixed way. Technical data sheet Declaration of Conformity
149
Close

149 | Thermostatic mixer with female connections

Thermostatic mixer with female connections. Max. working pressure 10 bars, max. working temperature 85°C, temperature setting on mixed way 30-65°C. Side hot/cold water inlets, lower mixed way. Technical data sheet Declaration of Conformity
Thermostatic mixer valve
Close

165 | Thermostatic mixer with tails on the three ways

Thermostatic mixer with tails on the three ways, check valve on hot/cold ways. Max.working pressure 10 bars, max. working temperature 85°C. Temperature setting on mixed way 30-65°C. Side hot/cold water inlets, lower mixed way. Technical data sheet Declaration of Conformity
Thermostatic mixer with male connections.
Close

166 | Thermostatic mixer with male connections

Thermostatic mixer with male connections. Max. working pressure 10 bars, max. working temperature 85°C, temperature setting on mixed way 30-65°C. Side hot/cold water inlets, lower mixed way. Technical data sheet Declaration of Conformity
C298
Close

C298 | Calibration and balancing valve for heating – 1”M e 1”F connections

Calibration and balancing valve for heating, cooling and sanitary systems. Equipped with a calibration display and antitampering setting lock. When the value of the valve is set, it can be opened or closed, but not at a higher kv value than the set one. PN20, max. working temperature 120°C, EPDM gaskets, brass body. 1”M e 1”F connections (revolving nut). Declaration of Conformity
C299
Close

C299 | Calibration and balancing valve for heating, cooling and sanitary systems

Calibration and balancing valve for heating, cooling and sanitary systems. Equipped with a calibration display and antitampering setting lock. When the value of the valve is set, it can be opened or closed, but not at a higher kv value than the set one. PN20, max. working temperature 120°C, EPDM gaskets,brass body. Technical data sheet Declaration of Conformity
Calibration and balancing valve with self-sealing measuring sockets for heating, cooling and sanitary
Close

C300 | Calibration and balancing valve with threaded connections and self-sealing measuring sockets for heating

Calibration and balancing valve with threaded connections and self-sealing measuring sockets for heating, cooling and sanitary systems. Equipped with a calibration display and antitampering setting lock. When the value of the valve is set, it can be opened or closed, but not at a higher kv value than the set one. PN20, max. working temperature 120°C, EPDM gaskets, brass body. Technical data sheet Declaration of Conformity
Calibration and balancing valve for heating, cooling and sanitary systems
Close

C301 | Calibration and balancing valve with flanged connections and self-sealing measuring sockets for heating

Calibration and balancing valve with flanged connections and self-sealing measuring sockets for heating, cooling and sanitary systems. Flanged body in cast iron. Equipped with a calibration display and antitampering setting lock. When the value of the valve is set, it can be opened or closed, but not at a higher kv value than the set one. PN16, max. working temperature 120°C, EPDM gaskets. Technical data sheet Declaration of Conformity