782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
0
People watching this product now!
Codes and dimensions
| Art. | Size | Delivery side | Boiler connection | System connection | Return connection | Code | |
| 782 | DN20 | R | 1”1/2 M | 1"1/2 F | 1” M | 93782AED05 | 1 |
| 782 | DN20 | L | 1”1/2 M | 1"1/2 F | 1” M | 93782AES05 | 1 |
Related products
R003 – Mixing group for high/low direct temperature unit
Mixing group for high/low direct temperature unit, suitable for radiators systems, fan coils, design radiators, radiation heating and boilers. The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump or with delivery pump to the right; the pump can be easily moved to the left. The group is supplied with a black PPE insulated shell.
Technical datasheet
Instruction Sheet
Declaration of Conformity
R005 – Anti-condensation mixing group
Anti-condensation mixing group, 1 “male connections. It is equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures. It can be ordered without pump, with asynchronous pump (not for sale in the EU), with electronic pump to the right or to the left-hand. The group includes an anti-condensation valve, 1”, available settings: 45 °, 55 °, 60 °, 70 °.
When placing the order please specify the requested temperature setting, by filling in the dotted line with the number corresponding to the temperature setting. For example, if you order R005 R with circulator P328 and 55 °anti-condensation, the code will be: 94R005AED55P328.
Technical datasheet
Instruction Sheet
Declaration of Conformity
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
Technical datasheet
3D Models
786 | Thermostatic mixing group
Thermostatic mixing group, consisting of a regulated 4-way mixing valve with 90° inlets, designed for pump and manifold connection. Adjustment ranges 20°C - 50°C: code 93786AE052050 / 30°C - 70°C: code 93786AE053070.
Technical datasheet
3D Models
785 | Brass manifold for pump groups
NOTE: in case of reduction for the boiler inlet connection, use art. 789.
Double-chamber brass manifold suitable for pump groups art. R001-R002-R003, complete with black EPP insulation shell. Art. 785 manifolds can be used individually or connected in series (up to 6) to serve multiple circuits, simplifying installation and reducing the overall footprint. The package includes nuts, bolts, and two O-rings for closing a single manifold or connecting multiple manifolds together.
NOTE: art. 790 end caps and art. 788 mounting bracket are not included.
Ordering examples:
1 single manifold: 1x art. 785 + 2x art. 790
2 manifolds in series: 2x art. 785 + 2x art. 790 + 2x art. 173
3 manifolds in series: 3x art. 785 + 2x art. 790 + 4x art. 173
4 manifolds in series: 4x art. 785 + 2x art. 790 + 6x art. 173
5 manifolds in series: 5x art. 785 + 2x art. 790 + 8x art. 173
6 manifolds in series: 6x art. 785 + 2x art. 790 + 10x art. 173
Technical datasheet
Declaration of conformity
3D Models
M058 | Mixing group with fixed point regulating unit with circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity