R004 – Pump group with fixed-point mixing
Pump group with fixed-point mixing, complete with thermostatic mixing valve. By setting the operating temperature on the mixing valve, effective control of the system flow temperature is achieved when it differs from that of the heat generator. Two different thermostatic valves are available with different operating ranges (20-50°C / 30-70°C). The circulator, with 1”1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous reading of the flow and return temperatures (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, with the flow circulator on the right or left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the group is supplied with a black EPP insulating shell.
When ordering, please specify the required temperature (between 20-50°C or 30-70°C), replacing the dots (where present) with the number corresponding to the temperature; for example, when ordering: R004 DX with P328 circulator and 20-50°C temperature, the code will be: 94R004AED55P328 (in the case of 30-70°C temperature, indicate 70 instead of the dots).
3D Models

Cod. 93R004…

Cod. 94R004…
| Art. | Size | Delivery side | Boiler connection | System connection | Code | Pump | Circulator contol signal | |||
| ON/OFF | PWM | |||||||||
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..05 | NO PUMP | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P327 | Wilo Para 25/8 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED55P329 | Taco ES2 25/60 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P330 | Wilo Para 25/7 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P331 | Shinoo GPA 25/70 III* | ✔ | ✔ | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..05 | NO PUMP | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P327 | Wilo Para 25/8 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED55P329 | Taco ES2 25/60 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P330 | Wilo Para 25/7 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P331 | Shinoo GPA 25/70 III* | ✔ | ✔ | 1 | |
The product with UPS 25/65 pump is sold in non-EU countries that have not joined the EUP regulations.
* PWM signal cable not included. To be purchased separately (see cables)when connecting to a PWM signal controller.
You may also like…
P320 – P321 | Asynchronous circulator
P327 | Electronic circulator WILO PARA RS 25/8
Electronic circulator WILO PARA RS 25/8, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves. Power supply cable included.
Instruction Sheet
P328 | Grundfos UPM3 HYBRID 25-70 electronic circulator
Grundfos UPM3 HYBRID 25-70 electronic circulator, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves, AUTO ADAPT, PWM signal. POWER SUPPLY CABLE INCLUDED. The pump can be controlled via PWM signal. PWM signal cable NOT INCLUDED.
Instruction Sheet
P330 | Electronic circulator WILO PARA RS 25/7
Related products
R001 | Pump group with variable point mixing
Pump group with variable point mixing, complete with a 3-way mixing valve regulated by a three-point modulating bidirectional rotary electric actuator, connectable to weather-compensated controllers; the valve features a bypass that draws water from the system return and feeds it into the flow circuit to achieve the desired fluid temperature. The circulator, with 1 1/2” connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous flow and return temperature readings (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, or with the flow circulator on the right or left (in case of on-site changes, please follow the instructions in the technical data sheet included in the packaging); the unit is supplied with a black EPP insulating shell.
The supply includes actuator art. 787 (specify 230 or 24 V voltage).
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
R003 – Booster set for high/low direct temperature
High/low direct temperature control unit, suitable for systems with radiators, fan coils and heated towel rails. The circulator, with 1½-inch connections, is available in either an asynchronous (not available for sale in the EU) or electronic version. The pump set features two ball shut-off valves with built-in thermometers for instantaneous reading of flow and return temperatures (the return ball valve includes an integrated check valve) and a ball valve to isolate the circulator. The pump set can be ordered without a circulator or with the flow circulator on the right; the circulator can be easily moved to the left. The set is supplied with a black EPP insulation shell.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
Technical datasheet
789 | Flat seat female-female union
Flat seat female-female union complete with cap and gasket. Reduces the lower connection of items R001, R002, R003 and 785 from 1" to 1/2"F, 1"1/2 to 3/4"F or from 1"1/2 to 1"F.
Technical datasheet
Declaration of conformity
796 | Flat seat union complete with swivel cap nut and gasket
Flat seat union female-female complete with swivel cap nut and gasket. Reduces from 1"F (flat seat seal) to 1" 1/2"F.
Technical datasheet
Declaration of conformity
797 | Male-female flat seat fitting complete with gaskets
Male-female flat seat fitting complete with gaskets on both sides. Reduces from 1" 1/2"M to 1"F.
Technical datasheet
Declaration of conformity
M061 | Compact mixing group
ICMA mixing group M061 is designed for underfloor heating systems, in combination with distribution manifolds.
It maintains the fluid delivery temperature stable to the set value. The delivery temperature adjustment is done simply by means of a graduated cap.
Available with or without 3/4” water filling and drain tap
Technical datasheet
Instruction Sheet
Declaration of Conformity
K063 | Fixed point temperature regulating group
Fixed point temperature regulating group. Max.pressure valve and flowmeter. Thermostatic head 20-50°C with remote sensor and cockpit art.189 with 1/2” connection.
Technical datasheet
Declaration of Conformity