- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
793 | Mixing valve for underfloor heating kit
Mixing valve for underfloor heating kit. Operating temperature 20°C –
53°c. Max. Operating pressure: 10 bar.
Codes and dimensions
| Art. | Code | |
| 793 | 93793AE062050 | 1 |
You may also like…
M061 | Compact mixing group
ICMA mixing group M061 is designed for underfloor heating systems, in combination with distribution manifolds.
It maintains the fluid delivery temperature stable to the set value. The delivery temperature adjustment is done simply by means of a graduated cap.
Available with or without 3/4” water filling and drain tap
Technical datasheet
Instruction Sheet
Declaration of Conformity
Related products
R001 | Pump group with variable point mixing
Pump group with variable point mixing, complete with a 3-way mixing valve regulated by a three-point modulating bidirectional rotary electric actuator, connectable to weather-compensated controllers; the valve features a bypass that draws water from the system return and feeds it into the flow circuit to achieve the desired fluid temperature. The circulator, with 1 1/2” connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous flow and return temperature readings (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, or with the flow circulator on the right or left (in case of on-site changes, please follow the instructions in the technical data sheet included in the packaging); the unit is supplied with a black EPP insulating shell.
The supply includes actuator art. 787 (specify 230 or 24 V voltage).
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
R004 – Pump group with fixed-point mixing
Pump group with fixed-point mixing, complete with thermostatic mixing valve. By setting the operating temperature on the mixing valve, effective control of the system flow temperature is achieved when it differs from that of the heat generator. Two different thermostatic valves are available with different operating ranges (20-50°C / 30-70°C). The circulator, with 1”1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous reading of the flow and return temperatures (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, with the flow circulator on the right or left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the group is supplied with a black EPP insulating shell.
When ordering, please specify the required temperature (between 20-50°C or 30-70°C), replacing the dots (where present) with the number corresponding to the temperature; for example, when ordering: R004 DX with P328 circulator and 20-50°C temperature, the code will be: 94R004AED55P328 (in the case of 30-70°C temperature, indicate 70 instead of the dots).
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
Technical datasheet
786 | Thermostatic mixing group
Thermostatic mixing group, consisting of a regulated 4-way mixing valve with 90° inlets, designed for pump and manifold connection. Adjustment ranges 20°C - 50°C: code 93786AE052050 / 30°C - 70°C: code 93786AE053070.
Technical datasheet
3D Models
788 | Wall mounting kit for circulation pump groups
789 | Flat seat female-female union
Flat seat female-female union complete with cap and gasket. Reduces the lower connection of items R001, R002, R003 and 785 from 1" to 1/2"F, 1"1/2 to 3/4"F or from 1"1/2 to 1"F.
Technical datasheet
Declaration of conformity
K062 | Delivery pump group
Delivery pump group. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1”½ connections. The mixing unit includes safety thermostat (art. P310) and manual air vent (art. 705 1/2”), it can be installed on the left or right side of the manifold. 1” connection. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
Declaration of Conformity