K062 | Delivery pump group
Delivery pump group. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1”½ connections. The mixing unit includes safety thermostat (art. P310) and manual air vent (art. 705 1/2”), it can be installed on the left or right side of the manifold. 1” connection. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
0
People watching this product now!
Codes and dimensions
| Art. | Size | Code | Pump | ||
| K062 | 1" | 87K062PG06 | NO PUMP | 1 | |
| K062 | 1" | 87K062PG0640 | Grundfos UPS 25/40 | 1 | |
| K062 | 1" | 87K062PG0660 | Grundfos UPS 25/65 | 1 | |
| K062 | 1" | 87K062PGP328 | UPM3 Hybrid 25/70* | 1 |
The product with UPS 25/65 pump is sold in non-EU countries that have not joined the EUP regulations.
* PWM signal cable not included. To be purchased separately (see cables) when connected to a controller with PWM signal.
Related products
R001 | Pump group with variable point mixing
Pump group with variable point mixing, complete with a 3-way mixing valve regulated by a three-point modulating bidirectional rotary electric actuator, connectable to weather-compensated controllers; the valve features a bypass that draws water from the system return and feeds it into the flow circuit to achieve the desired fluid temperature. The circulator, with 1 1/2” connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous flow and return temperature readings (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, or with the flow circulator on the right or left (in case of on-site changes, please follow the instructions in the technical data sheet included in the packaging); the unit is supplied with a black EPP insulating shell.
The supply includes actuator art. 787 (specify 230 or 24 V voltage).
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
R005 – Anti-condensation mixing group
Anti-condensation mixing group, 1 “male connections. It is equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures. It can be ordered without pump, with asynchronous pump (not for sale in the EU), with electronic pump to the right or to the left-hand. The group includes an anti-condensation valve, 1”, available settings: 45 °, 55 °, 60 °, 70 °.
When placing the order please specify the requested temperature setting, by filling in the dotted line with the number corresponding to the temperature setting. For example, if you order R005 R with circulator P328 and 55 °anti-condensation, the code will be: 94R005AED55P328.
Technical datasheet
Instruction Sheet
Declaration of Conformity
785 | Brass manifold for pump groups
NOTE: in case of reduction for the boiler inlet connection, use art. 789.
Double-chamber brass manifold suitable for pump groups art. R001-R002-R003, complete with black EPP insulation shell. Art. 785 manifolds can be used individually or connected in series (up to 6) to serve multiple circuits, simplifying installation and reducing the overall footprint. The package includes nuts, bolts, and two O-rings for closing a single manifold or connecting multiple manifolds together.
NOTE: art. 790 end caps and art. 788 mounting bracket are not included.
Ordering examples:
1 single manifold: 1x art. 785 + 2x art. 790
2 manifolds in series: 2x art. 785 + 2x art. 790 + 2x art. 173
3 manifolds in series: 3x art. 785 + 2x art. 790 + 4x art. 173
4 manifolds in series: 4x art. 785 + 2x art. 790 + 6x art. 173
5 manifolds in series: 5x art. 785 + 2x art. 790 + 8x art. 173
6 manifolds in series: 6x art. 785 + 2x art. 790 + 10x art. 173
Technical datasheet
Declaration of conformity
3D Models
797 | Flat seat Male-Female connector with gaskets on both sides
Flat seat Male-Female connector with gaskets on both sides. Reduction from 1” ½ M to 1”F.
Technical datasheet
Declaration of Conformity
M055 | Fixed point three-way mixing group with safety thermostat and thermostatic head
Fixed point three-way mixing group with maximum pressure differential valve and flow meter. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. The mixing unit includes safety thermostat (art. P310), thermostatic head 20°-50°C with remote sensor art.995. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
Instruction Sheet
Declaration of Conformity
P310 | Safety thermostat
Safety thermostat. Suitable for underfloor systems with high temperature boiler supply. It stops the pump when reaching 50˚C.
Technical datasheet