- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
R001 | Pump group with variable point mixing
Pump group with variable point mixing, complete with a 3-way mixing valve regulated by a three-point modulating bidirectional rotary electric actuator, connectable to weather-compensated controllers; the valve features a bypass that draws water from the system return and feeds it into the flow circuit to achieve the desired fluid temperature. The circulator, with 1 1/2” connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous flow and return temperature readings (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, or with the flow circulator on the right or left (in case of on-site changes, please follow the instructions in the technical data sheet included in the packaging); the unit is supplied with a black EPP insulating shell.
The supply includes actuator art. 787 (specify 230 or 24 V voltage).
3D Models

Cod. 93R001…53

Cod. 94R001…53
| Art. | Size | Actuator voltage | Delivery side | Boiler connection | System connection | Code | Pump | Circulator control signal | |||
| ON/OFF | PWM | ||||||||||
| R001 | DN20 | 230 volt | R | 1"1/2 M | 3/4 F | 93R001AED53 | NO PUMP | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 1" M | 93R001MD53 | NO PUMP | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 3/4 F | 93R001AEDP32753 | Wilo Para 25/8 | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 3/4 F | 93R001AEDP32953 | Taco ES2 25/60 | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 3/4 F | 93R001AEDP33053 | Wilo Para 25/7 | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 3/4 F | 93R001AEDP33153 | Shinoo GPA 25/70 III* | ✔ | ✔ | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 1” M | 94R001AED53 | NO PUMP | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 1” M | 94R001AEDP32753 | Wilo Para 25/8 | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 1” M | 94R001AEDP33053 | Wilo Para 25/7 | ✔ | X | 1 | |
| R001 | DN20 | 230 volt | R | 1"1/2 M | 3/4 F | 94R001AEDP33153 | Shinoo GPA 25/70 III* | ✔ | ✔ | 1 | |
The product with UPS 25/65 pump is sold in non-EU countries that have not joined the EUP regulations.
* PWM signal cable not included. To be purchased separately (see cables) when connecting to a PWM signal controller.
You may also like…
P320 – P321 | Asynchronous circulator
P327 | Electronic circulator WILO PARA RS 25/8
Electronic circulator WILO PARA RS 25/8, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves. Power supply cable included.
Instruction Sheet
P328 | Grundfos UPM3 HYBRID 25-70 electronic circulator
Grundfos UPM3 HYBRID 25-70 electronic circulator, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves, AUTO ADAPT, PWM signal. POWER SUPPLY CABLE INCLUDED. The pump can be controlled via PWM signal. PWM signal cable NOT INCLUDED.
Instruction Sheet
P330 | Electronic circulator WILO PARA RS 25/7
Related products
R005 – Anti-condensation mixing group
Anti-condensation circulation station, 1" male connections. The station consists of two ball valves with built-in thermometer for instant reading of flow and return temperature. The station can be ordered without circulator, with asynchronous circulator (not for sale in EU), with electronic circulator mounted on the right or left.
This item includes 1" anti-condensation valve, available in 45°, 55°, 60°, 70° settings.
When ordering, specify the required setting by adding the number corresponding to the setting in place of the dots; example when ordering: R005 DX with circulator P328 and 55° anti-condensation, the code will be: 94R005AED55P328.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
Technical datasheet
3D Models
786 | Thermostatic mixing group
Thermostatic mixing group, consisting of a regulated 4-way mixing valve with 90° inlets, designed for pump and manifold connection. Adjustment ranges 20°C - 50°C: code 93786AE052050 / 30°C - 70°C: code 93786AE053070.
Technical datasheet
3D Models
796 | Flat seat union complete with swivel cap nut and gasket
Flat seat union female-female complete with swivel cap nut and gasket. Reduces from 1"F (flat seat seal) to 1" 1/2"F.
Technical datasheet
Declaration of conformity
797 | Male-female flat seat fitting complete with gaskets
Male-female flat seat fitting complete with gaskets on both sides. Reduces from 1" 1/2"M to 1"F.
Technical datasheet
Declaration of conformity
M055 | Fixed point three-way mixing group with safety thermostat and thermostatic head
Fixed point three-way mixing group with maximum pressure differential valve and flow meter. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. The mixing unit includes safety thermostat (art. P310), thermostatic head 20°-50°C with remote sensor art.995. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
Instruction Sheet
Declaration of Conformity
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
K062 | Delivery pump group
Delivery pump group. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1”½ connections. The mixing unit includes safety thermostat (art. P310) and manual air vent (art. 705 1/2”), it can be installed on the left or right side of the manifold. 1” connection. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
Declaration of Conformity