- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
K076 208L | Stainless steel manifold kit with manual/thermostatic regulation and shut-off and flow regulators – M30
Stainless steel manifold kit with manual/thermostatic adjustment and flow meters. Includes: 2 ball valves (art. 216), ball valve nozzle attachment with flat seat seal held with O-ring on the manifold, 2 fixing brackets (art. 208L) with anti-vibration gaskets, 2 3/8” manual air vent valves (art. 701), 2 1/2” water drain taps (art. 172). Thread for fittings 3/4 Euroconus. Choose electrothermal controls with 30×1.5 connection. Compatible with ICMA M30 electrothermal actuators (ns. art. 979, 977), Innoakt INN920066PL, Taconova NOVADRIVE 257.2855.000, Taconova TOPDRIVE 257.2055.000, Caleffi 656102 (4 wires), Siemens STA321.65L10, Imi hydronic Emo-t and Intellisys MCA230 (4 wires), Danfoss 088H3220.
Not compatible with box art. 196
Installation guide for the M30 actuator
Codes and dimensions
| Art. | Head Connection | Outlets | Code | Connection Thread | Manifold total lenght | Cabinet recommended art. 196 |
| K076 208L | 1” | 2 | 87K076PG32 208L | 3/4” EK. | 285 mm | 500 mm |
| K076 208L | 1” | 3 | 87K076PH32 208L | 3/4” EK. | 335 mm | 500 mm |
| K076 208L | 1” | 4 | 87K076PJ32 208L | 3/4” EK. | 385 mm | 500 mm |
| K076 208L | 1” | 5 | 87K076PQ32 208L | 3/4” EK. | 435 mm | 700 mm |
| K076 208L | 1” | 6 | 87K076PK32 208L | 3/4” EK. | 485 mm | 700 mm |
| K076 208L | 1” | 7 | 87K076PR32 208L | 3/4” EK. | 535 mm | 700 mm |
| K076 208L | 1” | 8 | 87K076PL32 208L | 3/4” EK. | 585 mm | 700 mm |
| K076 208L | 1” | 9 | 87K076PS32 208L | 3/4” EK. | 635 mm | 850 mm |
| K076 208L | 1” | 10 | 87K076PM32 208L | 3/4” EK. | 685 mm | 850 mm |
| K076 208L | 1” | 11 | 87K076PT32 208L | 3/4” EK. | 735 mm | 850 mm |
| K076 208L | 1” | 12 | 87K076PU32 208L | 3/4” EK. | 785 mm | 1000 mm |
| K076 208L | 1” | 13 | 87K076PV32 208L | 3/4” EK. | 835 mm | 1000 mm |
| K076 208L | 1” | 14 | 87K076PW32 208L | 3/4” EK. | 885 mm | 1200 mm |
| K076 208L | 1” | 15 | 87K076PY32 208L | 3/4” EK. | 935 mm | 1200 mm |
Related products
K054 – K056 – K058 | Pre-assembled group with box for radiant panel systems and radiators
Pre-assembled group with box. For radiant panel systems with low temperature circuits and for radiators with high temperature circuits, high temperature supply, fixed point mixing unit. It is supplied with pump P328 (Grundfos UPM3 Hybrid) and safety thermostat P310 installed in the box. Choose electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
K060 | Pre-assembled for radiant panel systems with low temperature circuits
Pre-assembled group with box. For radiant panel systems with low temperature circuits, high temperature supply, fixed point mixing unit. It is supplied with pump P328 (Grundfos UPM3 Hybrid) and safety thermostat P310 installed in the box. Choose electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
K031 – K032 | Kit collettori – Regolazione ed intercettazione manuale/termostatizzabile – Con valvola a squadra
Manifolds unit with memory flowmeters and valves with thermostatic option.
It includes: 2 ball valves (art.225), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1/2” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
ROHS Declaration
K023 | Manifolds unit with memory flowmeters and valves with thermostatic option – With angle ball valve
Manifolds unit with memory flowmeters and valves with thermostatic option. It Includes: 2 ball valves (art.225), connection to the ball valve with gasket with flat seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 built-in manual air vents with o-ring (art.705), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
ROHS Declaration
K013 – K014 | Manifolds unit with memory flowmeters and valves with thermostatic option
Manifolds unit with memory flowmeters and valves with thermostatic option. Brackets with antivibration supports (art.208). The flow regulators allow to close and regulate the flow.
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
ROHS Declaration
1001 – 1002 | Return manifold with manual valves and valves with thermostatic option
Return manifold with manual valves and valves with thermostatic option. Male outlets. Interaxe: 50 mm. Suitable for 3/4” Euroconus or M24x1,5 fittings. Choose electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
1013 – 1014 | Delivery manifold with flowmeters
Delivery manifold with flowmeters. Male outlets. Interaxe: 50 mm.
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Technical datasheet
Declaration of Conformity
ROHS Declaration
1015 | Delivery manifold with flowmeters
Delivery manifold with flowmeters. Outlets for 1/2” air vent (art.700) and 1/2” drain cock (art.172). Male outlets. Interaxe: 50 mm.
Suitable for 3/4” Euroconus fittings.
Technical datasheet
Declaration of Conformity
ROHS Declaration