Art. | Head connection | Outlets | Code | Fitting thread | |
1013 | 1" | 1 | 871013PF06 | 3/4” EK. | 1 |
1013 | 1" | 2 | 871013PG06 | 3/4” EK. | 1 |
1013 | 1" | 3 | 871013PH06 | 3/4” EK. | 1 |
1013 | 1" | 4 | 871013PJ06 | 3/4” EK. | 1 |
1013 | 1" | 5 | 871013PQ06 | 3/4” EK. | 1 |
1013 | 1" | 6 | 871013PK06 | 3/4” EK. | 1 |
1013 | 1" | 7 | 871013PR06 | 3/4” EK. | 1 |
1013 | 1" | 8 | 871013PL06 | 3/4” EK. | 1 |
1013 | 1" | 9 | 871013PS06 | 3/4” EK. | 1 |
1013 | 1" | 10 | 871013PM06 | 3/4” EK. | 1 |
1013 | 1" | 11 | 871013PT06 | 3/4” EK. | 1 |
1013 | 1" | 12 | 871013PU06 | 3/4” EK. | 1 |
1013 | 1" | 13 | 871013PV06 | 3/4” EK. | 1 |
1013 | 1" | 14 | 871013PW06 | 3/4” EK. | 1 |
1013 | 1" | 15 | 871013PY06 | 3/4” EK. | 1 |
1014 | 1" | 1 | 871014PF06 | M24x1,5 | 1 |
1014 | 1" | 2 | 871014PG06 | M24x1,5 | 1 |
1014 | 1" | 3 | 871014PH06 | M24x1,5 | 1 |
1014 | 1" | 4 | 871014PJ06 | M24x1,5 | 1 |
1014 | 1" | 5 | 871014PQ06 | M24x1,5 | 1 |
1014 | 1" | 6 | 871014PK06 | M24x1,5 | 1 |
1014 | 1" | 7 | 871014PR06 | M24x1,5 | 1 |
1014 | 1" | 8 | 871014PL06 | M24x1,5 | 1 |
1014 | 1" | 9 | 871014PS06 | M24x1,5 | 1 |
1014 | 1" | 10 | 871014PM06 | M24x1,5 | 1 |
1014 | 1" | 11 | 871014PT06 | M24x1,5 | 1 |
1014 | 1" | 12 | 871014PU06 | M24x1,5 | 1 |
1014 | 1" | 13 | 871014PV06 | M24x1,5 | 1 |
1014 | 1" | 14 | 871014PW06 | M24x1,5 | 1 |
1014 | 1" | 15 | 871014PY06 | M24x1,5 | 1 |
1013 – 1014 | Delivery manifold with flowmeters
Delivery manifold with flowmeters. Male outlets. Interaxe: 50 mm.
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Codes and dimensions
Related products
K009 – K010 | Manifolds unit with adjustment lockshields and valves with thermostatic option
Manifolds unit with adjustment lockshields and valves with thermostatic option. Outlets for 1/2” air vent (art.700) and 1/2” drain cock (art.172). Brackets with anti-vibration supports (art.208).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose electrothermic actuators with 28x1,5 connection thread.
Technical data sheet
Declaration of Conformity
K021 – K022 | Manifolds unit with adjustment lockshields – With straight balla valve
Manifolds unit with adjustment lockshields and valves with thermostatic option.
It includes: 2 ball valves (art.215), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 built-in manual air vents with o-ring (ns.art.705), 2 1/2” drain cocks (Ns.art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206). Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical data sheet
Declaration of Conformity
1015 – 1016 | Delivery manifold with flowmeters
Delivery manifold with flowmeters. Outlets for 1/2” air vent (art.700) and 1/2” drain cock (art.172). Male outlets. Interaxe: 50 mm.
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Technical data sheet
Declaration of Conformity
K031 – K032 | Manifolds unit with memory flowmeters and valves with thermostatic option – With straight valve
Manifolds unit with memory flowmeters and valves with thermostatic option.
It includes: 2 ball valves (art.215), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1/2” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical data sheet
Declaration of Conformity
K021 – K022 | Manifolds unit with adjustment lockshields – With angle ball valve
Manifolds unit with adjustment lockshields and valves with thermostatic option.
It includes: 2 ball valves (art.225), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 built-in manual air vents with o-ring (ns.art.705), 2 1/2” drain cocks (Ns.art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206). Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical data sheet
Declaration of Conformity
A2K013 | Pre-assembled group for radiant panel systems with low temperature circuits
Pre-assembled group for radiant panel systems with low temperature circuits, supplied at high-temperature with fixed-point two-way mixing system. It is supplied without circulator and complete with thermostatic head 20°-50°C with remote sensor.
Choose thermostatic and electrothermic actuators with M28x1,5 connection thread.
Combinable with pumps P320, P321, P326, P327, P328, P330 (page 182).
Technical data sheet
1011 – 1012 | Delivery manifold with micrometric regulation lockshields
Delivery manifold with micrometric regulation lockshields. Outlets for 1/2” air vent (art.700) and 1/2” drain cock (art.172). Male outlets. Interaxe: 50 mm. Suitable for 3/4” Euroconus or M24x1,5 fittings.
Technical data sheet
Declaration of Conformity
K005 – K006 | Manifolds unit with adjustment lockshields and valves with thermostatic option
Manifolds unit with adjustment lockshields and valves with thermostatic option. Brackets with anti-vibration supports (art.208).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose electrothermic actuators with 28x1,5 connection thread.
Technical data sheet
Declaration of Conformity