- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
R004 – Mixing group with fixed point regulating unit
Mixing group with fixed point regulating unit, equipped with thermostatic mixing valve. By setting the working temperature on the mixing valve, you get an effective control of the plant delivery temperature when it is different from the heat generator one. Two thermostatic valves are available with different working temperature (20-50°C / 30-70°C). The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump, with delivery pump to the right or to the left-hand (in case of any changes on site please follow the technical sheet instructions included in the package); the group is supplied with a black PPE insulated shell.
When placing the order please specify the requested temperature (between 20-50 °C or 30-70 °C), by filling in the dotted line (between the pump position and the pump code) with the number corresponding to the temperature. For example, if you order R004 R with circulator P328 and temperature 20°-50 ° C, the code will be: 94R004AED55P328 (in case of temperature 30-70 ° C please fill in the dotted line with 70).
0
People watching this product now!

Cod. 93R004…

Cod. 94R004…
| Art. | Size | Delivery side | Boiler connection | System connection | Code | Pump | Circulator contol signal | |||
| ON/OFF | PWM | |||||||||
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..05 | NO PUMP | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1"M | 93R004AFD55P321 | Grundfos UPS 25/65 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P321 | Grundfos UPS 25/65 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P327 | Wilo Para 25/8 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P328 | UPM3 Hybrid 25/70 * | ✔ | ✔ | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED55P329 | Taco ES2 25/60 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P330 | Wilo Para 25/7 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 3/4”F | 93R004AED..P331 | Shinoo GPA 25/70 III | ✔ | ✔ | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..05 | NO PUMP | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P321 | Grundfos UPS 25/65 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P327 | Wilo Para 25/8 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P328 | UPM3 Hybrid 25/70* | ✔ | ✔ | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED55P329 | Taco ES2 25/60 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P330 | Wilo Para 25/7 | ✔ | X | 1 | |
| R004 | DN20 | R | 1"1/2 M | 1”M | 94R004AED..P331 | Shinoo GPA 25/70 III | ✔ | ✔ | 1 | |
The product with UPS 25/65 pump is sold in non-EU countries that have not joined the EUP regulations.
* PWM signal cable not included. To be purchased separately (see cables)when connecting to a PWM signal controller.
You may also like…
P320 – P321 | Asynchronous circulator
P327 | Electronic circulator WILO PARA RS 25/8
Electronic circulator WILO PARA RS 25/8, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves. Power supply cable included.
Instruction Sheet
P328 | Grundfos UPM3 HYBRID 25-70 electronic circulator
Grundfos UPM3 HYBRID 25-70 electronic circulator, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves, AUTO ADAPT, PWM signal. POWER SUPPLY CABLE INCLUDED. The pump can be controlled via PWM signal. PWM signal cable NOT INCLUDED.
Instruction Sheet
P330 | Electronic circulator WILO PARA RS 25/7
Related products
782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
Technical datasheet
798 | Flat seat Male-Female union with revolving nut and gasket
Flat seat Male-Female union with revolving nut and gasket. Reduction from 1” ½ F to 1”M.
Technical datasheet
Declaration of Conformity
K062 | Delivery pump group
Delivery pump group. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1”½ connections. The mixing unit includes safety thermostat (art. P310) and manual air vent (art. 705 1/2”), it can be installed on the left or right side of the manifold. 1” connection. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
Declaration of Conformity
P310 | Safety thermostat
Safety thermostat. Suitable for underfloor systems with high temperature boiler supply. It stops the pump when reaching 50˚C.
Technical datasheet
787 | Electric servomotor
3-point rotating electric servomotor (modulating and bidirectional). It is installed on the mixing valve by means of a screw. Rotation angle 90°. The servomotor can also work manually by means of its switch. For the proper functioning and connection please refer to the instructions in the technical sheet.
Technical datasheet