- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
R002 – Mixing group with fixed point regulating unit
Mixing group with fixed point regulating unit. It is provided with a three way mixing valve regulated by a thermostatic head with remote sensor art. 995 to be placed in contact with or by immersion in the system delivery pipe according to which the desired temperature is set (working temperature range 20°C – 50°C). The valve has a by-pass which brings a portion of the return side flow into the delivery side to obtain the desired temperature of the fluid. The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump, with delivery pump to the right or to the left-hand (in case of any changes on site please follow the technical sheet instructions included in the package); the group is supplied with a black PPE insulated shell. The mixing unit is supplied with the thermostatic head art. 995 with 30×1,5 connections.

Cod. 93R002…

Cod. 94R002…
Art. | Size | Delivery side | Boiler connection | System connection | Code | Pump | Circulator control signal | |||
ON/OFF | PWM | |||||||||
R002 | DN20 | R | 1"1/2 M | 3/4 F | 93R002AED05 | NO PUMP | ✔ | X | 1 | |
R002 | DN20 | R | 1"1/2 M | 3/4 F | 93R002AEDP321 | Grundfos UPS 25/65 | ✔ | X | 1 | |
R002 | DN20 | R | 1"1/2 M | 3/4 F | 93R002AEDP327 | Wilo Para 25/8 | ✔ | X | 1 | |
R002 | DN20 | R | 1"1/2 M | 3/4 F | 93R002AEDP328 | UPM3 Hybrid 25/70 * | ✔ | ✔ | 1 | |
R002 | DN20 | R | 1"1/2 M | 3/4 F | 93R002AEDP330 | Wilo Para 25/7 | ✔ | X | 1 | |
R002 | DN20 | R | 1"1/2 M | 1” M | 94R002AED05 | NO PUMP | ✔ | X | 1 | |
R002 | DN20 | R | 1"1/2 M | 1” M | 94R002AEDP321 | Grundfos UPS 25/65 | ✔ | X | 1 | |
R002 | DN20 | R | 1"1/2 M | 1” M | 94R002AEDP327 | Wilo Para 25/8 | ✔ | X | 1 | |
R002 | DN20 | R | 1"1/2 M | 1” M | 94R002AEDP328 | UPM3 Hybrid 25/70* | ✔ | ✔ | 1 | |
R002 | DN20 | R | 1"1/2 M | 1” M | 94R002AEDP330 | Wilo Para 25/7 | ✔ | X | 1 |
The product with UPS 25/65 pump is sold in non-EU countries that have not joined the EUP regulations.
* PWM signal cable not included. To be purchased separately (see cables)when connecting to a PWM signal controller.
You may also like…
P320 – P321 | Asynchronous circulator
P327 | Electronic circulator WILO PARA RS 25/8
Electronic circulator WILO PARA RS 25/8, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves. Power supply cable included.
Instruction Sheet
P328 | Grundfos UPM3 HYBRID 25-70 electronic circulator
Grundfos UPM3 HYBRID 25-70 electronic circulator, interaxe distance 130 mm. Variable pressure, constant pressure, contant curves, AUTO ADAPT, PWM signal. POWER SUPPLY CABLE INCLUDED. The pump can be controlled via PWM signal. PWM signal cable NOT INCLUDED.
Instruction Sheet
P330 | Electronic circulator WILO PARA RS 25/7
Related products
R001 – Mixing group with variable point regulating unit
Mixing group with variable point regulating unit. It is provided with a three way mixing valve regulated by a 3-point modulating and bidirectional rotating electric servomotor, connectable to regulating control units; the valve has a By-Pass which brings a portion of the return side flow into the delivery side to obtain the desired temperature of the fluid. The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump, with delivery pump to the right or to the left-hand (in case of any changes on site please follow the technical sheet instructions included in the package); the group is supplied with a black PPE insulated shell.
The mixing unit is supplied with the servomotor art. 787 (230 or 24 voltage).
Technical datasheet
Instruction Sheet
Declaration of Conformity
173 | End cap with O-ring
End cap with O-ring to close 1” exits of manifold art. 785.
Declaration of Conformity
797 | Flat seat Male-Female connector with gaskets on both sides
Flat seat Male-Female connector with gaskets on both sides. Reduction from 1” ½ M to 1”F.
Technical datasheet
Declaration of Conformity
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
K062 | Delivery pump group
Delivery pump group. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1”½ connections. The mixing unit includes safety thermostat (art. P310) and manual air vent (art. 705 1/2”), it can be installed on the left or right side of the manifold. 1” connection. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
Declaration of Conformity
P310 | Safety thermostat
Safety thermostat. Suitable for underfloor systems with high temperature boiler supply. It stops the pump when reaching 50˚C.
Technical datasheet
787 | Electric servomotor
3-point rotating electric servomotor (modulating and bidirectional). It is installed on the mixing valve by means of a screw. Rotation angle 90°. The servomotor can also work manually by means of its switch. For the proper functioning and connection please refer to the instructions in the technical sheet.
Technical datasheet