- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
477 | Insulation cups for 1″ and 1″1/4 stainless steel manifolds
Insulators for 1” and 1”1/4 stainless steel manifolds from 2 up to 15 outlets. The insulators can be cut, to insulate the manifolds carrying a lower outlet number. Holes on both sides with 50 mm interaxe.
Codes and dimensions
| Art. | Head connection | Code EUROCONUS | |
| 477 | 1" | 87477AF66 | 1 |
| 477 | 1"1/4 | 87477AG66 | 1 |
Related products
A2K013 | Pre-assembled group for radiant panel systems with low temperature circuits
Pre-assembled group for radiant panel systems with low temperature circuits, supplied at high-temperature with fixed-point two-way mixing system. It is supplied without circulator and complete with thermostatic head 20°-50°C with remote sensor.
Choose thermostatic and electrothermic actuators with M28x1,5 connection thread.
Combinable with pumps P320, P321, P326, P327, P328, P330 (page 182).
ROHS Declaration
K025 – K026 | Manifolds unit with memory flowmeters and valves with thermostatic option – With angle ball valve
Manifolds unit with memory flowmeters and valves with thermostatic option. It includes: 2 ball valves (art. 225), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1” male/female intermediate fittings with revolving connection (art.204). Conical sealing gasket. Art.204 can be assembled between manifold and ball valve. 2 3/8” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
ROHS Declaration
K031 – K032 | Manifolds unit with memory flowmeters and valves with thermostatic option – With straight valve
Manifolds unit with memory flowmeters and valves with thermostatic option.
It includes: 2 ball valves (art.215), connection to the ball valve with gasket with plane seat and o-ring, 2 brackets (art.208) with anti-vibration supports, 2 1/2” automatic air vents (art.700), 2 1/2” drain cocks (art.172), 2 1” thermometer caps with o-ring (art.185), 2 0-60° thermometers (art.206).
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Choose thermostatic and electrothermic actuators with 28x1,5 connection thread.
Technical datasheet
Declaration of Conformity
ROHS Declaration
K075 | Stainless steel manifold kit with manual/thermostatic regulation and shut-off and flow regulators
Stainless steel manifold kit with manual/thermostatic adjustment and flow meters. Includes: 2 ball valves (art. 216), nozzle attachment of the
ball valve with flat seat gasket held with O-ring on the manifold, 2 fixing brackets (art. 208) with anti-vibration gaskets, 2 3/8” manual air vent valves (art. 701), 2 1/2” water drain taps (art. 172). Threaded connection for 3/4-inch Euroconus fittings. Select electrothermal controls with a 28x1.5 connection.
Technical datasheet
Instruction sheet
Declaration of conformity
ROHS Declaration
3D Models
Installation guide for the M28 actuator
K077 208L | Stainless steel manifold kit with manual/thermostatic regulation and shut-off and flow regulators
Stainless steel manifold kit with manual/thermostatic adjustment and
shut-off, featuring flow meters. Includes: 2 ball valves (art. 216), ball valve nozzle attachment with flat seat seal held with O-ring on the manifold, 2 fixing brackets (art. 208L) with anti-vibration gaskets, 2 automatic 3/8” air vent valves (art. 700), 2 1/2” water drain taps (art. 172). Threaded connection for 3/4-inch Euroconus fittings. Select electrothermal controls with a 28x1.5 connection.
Technical datasheet
Instruction sheet
Declaration of conformity
ROHS Declaration
Installation guide for the M28 actuator
1005 – 1006 | Delivery manifold with micrometric regulation lockshields
Delivery manifold with micrometric regulation lockshields. Male outlets. Interaxe: 50 mm.
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Technical datasheet
Declaration of Conformity
ROHS Declaration
1013 – 1014 | Delivery manifold with flowmeters
Delivery manifold with flowmeters. Male outlets. Interaxe: 50 mm.
Suitable for 3/4” Euroconus or M24x1,5 fittings.
Technical datasheet
Declaration of Conformity
ROHS Declaration
1011 | Delivery manifold with micrometric regulation lockshields
Delivery manifold with micrometric regulation lockshields. Outlets for 1/2” air vent (art.700) and 1/2” drain cock (art.172). Male outlets. Interaxe: 50 mm. Suitable for 3/4” Euroconus fittings.
Technical datasheet
Declaration of Conformity
ROHS Declaration