787 | Electric servomotor
3-point rotating electric servomotor (modulating and bidirectional). It is installed on the mixing valve by means of a screw. Rotation angle 90°. The servomotor can also work manually by means of its switch. For the proper functioning and connection please refer to the instructions in the technical sheet.
Codes and dimensions
| Art. | Voltage | Code | |
| 787 | 230 volt | 82787BI53 | 1 |
| 787 | 24 volt AC | 82787BI54 | 1 |
Related products
R004 – Pump group with fixed-point mixing
Pump group with fixed-point mixing, complete with thermostatic mixing valve. By setting the operating temperature on the mixing valve, effective control of the system flow temperature is achieved when it differs from that of the heat generator. Two different thermostatic valves are available with different operating ranges (20-50°C / 30-70°C). The circulator, with 1”1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous reading of the flow and return temperatures (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, with the flow circulator on the right or left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the group is supplied with a black EPP insulating shell.
When ordering, please specify the required temperature (between 20-50°C or 30-70°C), replacing the dots (where present) with the number corresponding to the temperature; for example, when ordering: R004 DX with P328 circulator and 20-50°C temperature, the code will be: 94R004AED55P328 (in the case of 30-70°C temperature, indicate 70 instead of the dots).
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
R005 – Anti-condensation mixing group
Anti-condensation circulation station, 1" male connections. The station consists of two ball valves with built-in thermometer for instant reading of flow and return temperature. The station can be ordered without circulator, with asynchronous circulator (not for sale in EU), with electronic circulator mounted on the right or left.
This item includes 1" anti-condensation valve, available in 45°, 55°, 60°, 70° settings.
When ordering, specify the required setting by adding the number corresponding to the setting in place of the dots; example when ordering: R005 DX with circulator P328 and 55° anti-condensation, the code will be: 94R005AED55P328.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
788 | Wall mounting kit for circulation pump groups
797 | Male-female flat seat fitting complete with gaskets
Male-female flat seat fitting complete with gaskets on both sides. Reduces from 1" 1/2"M to 1"F.
Technical datasheet
Declaration of conformity
M058 | Mixing group with fixed point regulating unit with circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
M061 | Compact mixing group
ICMA mixing group M061 is designed for underfloor heating systems, in combination with distribution manifolds.
It maintains the fluid delivery temperature stable to the set value. The delivery temperature adjustment is done simply by means of a graduated cap.
Available with or without 3/4” water filling and drain tap
Technical datasheet
Instruction Sheet
Declaration of Conformity