- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
3D Models
0
People watching this product now!
Codes and dimensions
| Art. | Misura | Posizione mandata | Attacchi caldaia | Attacchi impianto | Attacchi ritorno | Codice | |
| 783 | DN20 | DX | 1”1/2 M | 1"1/2 F | 1” M | 93783AED05 | 1 |
| 783 | DN20 | SX | 1”1/2 M | 1"1/2 F | 1” M | 93783AES05 | 1 |
Related products
R004 – Mixing group with fixed point regulating unit
Mixing group with fixed point regulating unit, equipped with thermostatic mixing valve. By setting the working temperature on the mixing valve, you get an effective control of the plant delivery temperature when it is different from the heat generator one. Two thermostatic valves are available with different working temperature (20-50°C / 30-70°C). The pump has 1”1/2 connections and it can be asynchronous (not for sale in the EU) or electronic. The mixing group is also equipped with 2 interception ball valves with built-in thermometer to instantly read the delivery and return flow temperatures (the return ball valve has a built-in check valve). It can be ordered without pump, with delivery pump to the right or to the left-hand (in case of any changes on site please follow the technical sheet instructions included in the package); the group is supplied with a black PPE insulated shell.
When placing the order please specify the requested temperature (between 20-50 °C or 30-70 °C), by filling in the dotted line (between the pump position and the pump code) with the number corresponding to the temperature. For example, if you order R004 R with circulator P328 and temperature 20°-50 ° C, the code will be: 94R004AED55P328 (in case of temperature 30-70 ° C please fill in the dotted line with 70).
Technical datasheet
Instruction Sheet
Declaration of Conformity
782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
Technical datasheet
788 | Wall mounting kit for circulation pump groups
789 | Plane seat union with nut and gasket
1”1/2 plane seat union with nut and gasket. It reduces from 1”1/2 to 3/4” F or from 1”1/2 to 1” F the lower connection of art. R001, R002, R003 and 785.
Technical datasheet
Declaration of Conformity
M061 | Compact mixing group
ICMA mixing group M061 is designed for underfloor heating systems, in combination with distribution manifolds.
It maintains the fluid delivery temperature stable to the set value. The delivery temperature adjustment is done simply by means of a graduated cap.
Available with or without 3/4” water filling and drain tap
Technical datasheet
Instruction Sheet
Declaration of Conformity
787 | Electric servomotor
3-point rotating electric servomotor (modulating and bidirectional). It is installed on the mixing valve by means of a screw. Rotation angle 90°. The servomotor can also work manually by means of its switch. For the proper functioning and connection please refer to the instructions in the technical sheet.
Technical datasheet



