- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
3D Models
Codes and dimensions
| Art. | Misura | Posizione mandata | Attacchi caldaia | Attacchi impianto | Attacchi ritorno | Codice | |
| 783 | DN20 | DX | 1”1/2 M | 1"1/2 F | 1” M | 93783AED05 | 1 |
| 783 | DN20 | SX | 1”1/2 M | 1"1/2 F | 1” M | 93783AES05 | 1 |
Related products
R001 | Pump group with variable point mixing
Pump group with variable point mixing, complete with a 3-way mixing valve regulated by a three-point modulating bidirectional rotary electric actuator, connectable to weather-compensated controllers; the valve features a bypass that draws water from the system return and feeds it into the flow circuit to achieve the desired fluid temperature. The circulator, with 1 1/2” connections, can be asynchronous (not for sale in the EU) or electronic. The pump group is equipped with two ball shut-off valves with built-in thermometers for instantaneous flow and return temperature readings (a check valve is integrated into the return ball valve). The pump group can be ordered without a circulator, or with the flow circulator on the right or left (in case of on-site changes, please follow the instructions in the technical data sheet included in the packaging); the unit is supplied with a black EPP insulating shell.
The supply includes actuator art. 787 (specify 230 or 24 V voltage).
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
782 | Mixing group with variable point regulation unit
Mixing group with variable point regulation unit. It is provided with a three way mixing valve regulated by a rotating electric servomotor, connectable to every type of regulating control units. The valve has a By-Pass which brings a portion of the return side flow into the delivery side to recover heat and to balance the temperature.
PLEASE NOTE: the servomotor art. 787 is not included.
Technical datasheet
785 | Brass manifold for pump groups
NOTE: in case of reduction for the boiler inlet connection, use art. 789.
Double-chamber brass manifold suitable for pump groups art. R001-R002-R003, complete with black EPP insulation shell. Art. 785 manifolds can be used individually or connected in series (up to 6) to serve multiple circuits, simplifying installation and reducing the overall footprint. The package includes nuts, bolts, and two O-rings for closing a single manifold or connecting multiple manifolds together.
NOTE: art. 790 end caps and art. 788 mounting bracket are not included.
Ordering examples:
1 single manifold: 1x art. 785 + 2x art. 790
2 manifolds in series: 2x art. 785 + 2x art. 790 + 2x art. 173
3 manifolds in series: 3x art. 785 + 2x art. 790 + 4x art. 173
4 manifolds in series: 4x art. 785 + 2x art. 790 + 6x art. 173
5 manifolds in series: 5x art. 785 + 2x art. 790 + 8x art. 173
6 manifolds in series: 6x art. 785 + 2x art. 790 + 10x art. 173
Technical datasheet
Declaration of conformity
3D Models
796 | Flat seat union complete with swivel cap nut and gasket
Flat seat union female-female complete with swivel cap nut and gasket. Reduces from 1"F (flat seat seal) to 1" 1/2"F.
Technical datasheet
Declaration of conformity
M058 | Mixing group with fixed point regulating unit with circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
M060 | Mixing group with fixed point regulating unit with circulating pump and thermostatic with remote sensor
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-70°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
M054 | Fixed point three-way mixing group with thermostatic head
Fixed point three-way mixing group with maximum pressure differential valve and flow meter. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. The mixing unit includes thermostatic head 20°-70°C with remote sensor art.995. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.