- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
789 | Flat seat female-female union
Flat seat female-female union complete with cap and gasket. Reduces the lower connection of items R001, R002, R003 and 785 from 1″ to 1/2″F, 1″1/2 to 3/4″F or from 1″1/2 to 1″F.
Codici e dimensioni
| Art. | Misura | Codice | ||
| 789 | 1/2”F - 1” F | 82789AD05 | 1 | 100 |
| 789 | 3/4” F - 1”1/2 F | 82789AE05 | 1 | 50 |
| 789 | 1” F - 1”1/2 F | 82789AF05 | 1 | 50 |
Related products
R002 – Mixing group with fixed point regulating unit
Recirculation unit with fixed-point mixing, complete with a 3-way mixing valve controlled by a thermostatic head with a remote sensor (item no. 995), to be positioned in contact with or immersed in the system’s supply pipe in order to achieve the desired fluid temperature (adjustment range 20°C–50°C). The valve is equipped with a bypass that draws part of the water from the system return, introducing it into the supply circuit to achieve the desired fluid temperature. The circulator, with 1"1/2 connections, can be asynchronous (not for sale in the EU) or electronic. The booster unit is fitted with two ball shut-off valves with an integrated thermometer for instant reading of the supply and return temperatures (the return ball valve incorporates a check valve). The booster unit can be ordered without a circulator, with a supply circulator on the right or on the left (in case of on-site changes, please follow the disassembly instructions in the technical data sheet included in the packaging); the unit is supplied with a black PPE insulating shell. The supply of the unit includes the thermostatic head art. 995 with 30x1.5 connections.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
R003 – Booster set for high/low direct temperature
High/low direct temperature control unit, suitable for systems with radiators, fan coils and heated towel rails. The circulator, with 1½-inch connections, is available in either an asynchronous (not available for sale in the EU) or electronic version. The pump set features two ball shut-off valves with built-in thermometers for instantaneous reading of flow and return temperatures (the return ball valve includes an integrated check valve) and a ball valve to isolate the circulator. The pump set can be ordered without a circulator or with the flow circulator on the right; the circulator can be easily moved to the left. The set is supplied with a black EPP insulation shell.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
783 | Fixed-point mixing unit
Fixed-point mixing unit, complete with a 3-way mixing valve regulated by a thermostatic head with remote sensor Art. 995, used to set the desired mixed flow temperature (adjustment range 20°C-50°C). The valve is equipped with a bypass that draws water from the system return and feeds it into the flow circuit to achieve the required fluid temperature. NOTE: thermostatic head art. 995 is not included.
Technical datasheet
3D Models
785 | Brass manifold for pump groups
NOTE: in case of reduction for the boiler inlet connection, use art. 789.
Double-chamber brass manifold suitable for pump groups art. R001-R002-R003, complete with black EPP insulation shell. Art. 785 manifolds can be used individually or connected in series (up to 6) to serve multiple circuits, simplifying installation and reducing the overall footprint. The package includes nuts, bolts, and two O-rings for closing a single manifold or connecting multiple manifolds together.
NOTE: art. 790 end caps and art. 788 mounting bracket are not included.
Ordering examples:
1 single manifold: 1x art. 785 + 2x art. 790
2 manifolds in series: 2x art. 785 + 2x art. 790 + 2x art. 173
3 manifolds in series: 3x art. 785 + 2x art. 790 + 4x art. 173
4 manifolds in series: 4x art. 785 + 2x art. 790 + 6x art. 173
5 manifolds in series: 5x art. 785 + 2x art. 790 + 8x art. 173
6 manifolds in series: 6x art. 785 + 2x art. 790 + 10x art. 173
Technical datasheet
Declaration of conformity
3D Models
797 | Male-female flat seat fitting complete with gaskets
Male-female flat seat fitting complete with gaskets on both sides. Reduces from 1" 1/2"M to 1"F.
Technical datasheet
Declaration of conformity
M061 | Compact mixing group
ICMA mixing group M061 is designed for underfloor heating systems, in combination with distribution manifolds.
It maintains the fluid delivery temperature stable to the set value. The delivery temperature adjustment is done simply by means of a graduated cap.
Available with or without 3/4” water filling and drain tap
Technical datasheet
Instruction Sheet
Declaration of Conformity
M054 | Fixed point three-way mixing group with thermostatic head
Fixed point three-way mixing group with maximum pressure differential valve and flow meter. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. The mixing unit includes thermostatic head 20°-70°C with remote sensor art.995. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.



