- Termostatic head
- Valves with thermostatic option for double pipe
- Double settings thermostatic valves for double pipe systems
- Thermostatic kit and thermostatic valves for double pipe systems
- Manual valves and lockshields for double pipe systems
- Four-way valves with thermostatic option for single pipe and double pipe systems
- Single pipe manual valves
- Fittings for copper, pex-al-pex, pex pipe, radiator eccentrics, elbow fittings, rosette
- Single/double pipe distributors for panel with built-in thermostatic group
- Radiator air vents
- Valves and lockshields for design radiators
- Chromed thermostatic head and rosettes with pipe cover
M055 | Fixed point three-way mixing group with safety thermostat and thermostatic head
Fixed point three-way mixing group with maximum pressure differential valve and flow meter. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. The mixing unit includes safety thermostat (art. P310), thermostatic head 20°-50°C with remote sensor art.995. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Codes and dimensions
| Art. | Size | Code | Pump | |
| M055 | 1" | 87M055PG0600 | NO PUMP | 1 |
| M055 | 1" | 87M055PG06P321W | Wilo Para 25/6 | 1 |
| M055 | 1" | 87M055PG06P327 | Wilo Para 25/8 | 1 |
| M055 | 1" | 87M055PG06P331 | Shinhoo 25/70* | 1 |
| M055 | 1" | 87M055PG06P329 | Taco ES2 25/60 | 1 |
| M055 | 1" | 87M055PG06P330 | Wilo Para 25/7 | 1 |
* PWM signal cable not included. Must be purchased separately (see cables), if connecting to a controller with a PWM signal.
Related products
R005 – Anti-condensation mixing group
Anti-condensation circulation station, 1" male connections. The station consists of two ball valves with built-in thermometer for instant reading of flow and return temperature. The station can be ordered without circulator, with asynchronous circulator (not for sale in EU), with electronic circulator mounted on the right or left.
This item includes 1" anti-condensation valve, available in 45°, 55°, 60°, 70° settings.
When ordering, specify the required setting by adding the number corresponding to the setting in place of the dots; example when ordering: R005 DX with circulator P328 and 55° anti-condensation, the code will be: 94R005AED55P328.
Technical datasheet
Instruction sheet
Declaration of conformity
3D Models
785 | Brass manifold for pump groups
NOTE: in case of reduction for the boiler inlet connection, use art. 789.
Double-chamber brass manifold suitable for pump groups art. R001-R002-R003, complete with black EPP insulation shell. Art. 785 manifolds can be used individually or connected in series (up to 6) to serve multiple circuits, simplifying installation and reducing the overall footprint. The package includes nuts, bolts, and two O-rings for closing a single manifold or connecting multiple manifolds together.
NOTE: art. 790 end caps and art. 788 mounting bracket are not included.
Ordering examples:
1 single manifold: 1x art. 785 + 2x art. 790
2 manifolds in series: 2x art. 785 + 2x art. 790 + 2x art. 173
3 manifolds in series: 3x art. 785 + 2x art. 790 + 4x art. 173
4 manifolds in series: 4x art. 785 + 2x art. 790 + 6x art. 173
5 manifolds in series: 5x art. 785 + 2x art. 790 + 8x art. 173
6 manifolds in series: 6x art. 785 + 2x art. 790 + 10x art. 173
Technical datasheet
Declaration of conformity
3D Models
796 | Flat seat union complete with swivel cap nut and gasket
Flat seat union female-female complete with swivel cap nut and gasket. Reduces from 1"F (flat seat seal) to 1" 1/2"F.
Technical datasheet
Declaration of conformity
M059 | Mixing group with fixed point regulating unit – With circulating pump and thermostatic head
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-50°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. Boiler delivery on left lower side, return on lower side. 1” delivery/return for radiant panel systems. Safety thermostat P310 not included.
Technical datasheet
Declaration of Conformity
M060 | Mixing group with fixed point regulating unit with circulating pump and thermostatic with remote sensor
Mixing group with fixed point regulating unit, circulating pump and thermostatic head 20°-70°C with remote sensor. Fixed point valve, adjustable flow rate optimising the flow to the panels. It can be equipped with asynchronous circulators (not sold in the EU) or electronic circulators with 1” ½ connections. Connection to delivery and return manifolds on the side. Suitable for installation in cabinets for manifolds with 110 mm. depth.
Technical datasheet
M061 | Compact mixing group
ICMA mixing group M061 is designed for underfloor heating systems, in combination with distribution manifolds.
It maintains the fluid delivery temperature stable to the set value. The delivery temperature adjustment is done simply by means of a graduated cap.
Available with or without 3/4” water filling and drain tap
Technical datasheet
Instruction Sheet
Declaration of Conformity